Product Features

  ETA Module 17plus 3AC433V / E-T-A Abschlussmodul - Partsmax Türkiye
 
 
 
 
Thermal-Magnetic Circuit Breaker 2210-T2.. Issue D www.e-t-a.de 3 - 17 3 Description Typical applications Ordering information Technical data One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Featuring a combi-foot design for both symmetric and asymmetric rail mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. This CBE can be supplied in current ratings up to 32 A with a choice of characteristic curves. All screw terminals are recessed for safety. Approved to CBE standard EN 60934 (IEC 60934). Process control equipment, robotics, machine tool control, communications systems, instrumentation. 2210-T2.. 1-pole 3-pole Type No. 2210 single and multipole thermal-magnetic circuit breaker Mounting T rail mounting Actuator design 2 toggle Number of poles 1 single pole protected 2 2-pole protected 3 3-pole protected Accessories 0 without accessories Terminal design (main contacts) K0 screw terminals Characteristic curve F1 fast acting: therm.1.01-1.4xIN; magn.2-4xIN DC (DC only) F2 fast acting: therm.1.01-1.4xIN; magn.3,5-6,5xIN AC/4,5-8,5xIN DC M1 standard delay: therm. 1.01-1.4xIN; magn. 6-12xIN AC, 7.8-15.6xIN DC T1 delayed: therm. 1.01-1.4xIN; magn. 10-20xIN AC Auxiliary contact design H without intermediate position Auxiliary contacts 1 with auxiliary contacts 2 auxiliary contacts on pole 1 only (multipole devices) Auxiliary contact function (see diagrams) 2 1 N/O contact 3 1 N/C contact Auxiliary contact - terminal design 1 screw terminals Current ratings 0.1...32 A 2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A ordering example For further details please see chapter: Technical Information Voltage rating AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V (UL: AC 277/480 V; DC 65 V) Current rating range 0.1...32 A for curves M1, T1 0.1...16 A for curves F1, F2 Auxiliary circuit 1 A, AC 240 V / DC 65 V, resistive Typical life 3 AC 433 V; AC 250 V: 0.1...25 A 10,000 operations at 1 x IN, inductive DC 65 V: 0.1...32 A 10,000 operations at 1 x IN, inductive 3 AC 433 V; AC 250 V: 32 A 10,000 operations at 1 x IN, resistive Ambient temperature -30...+60 °C (-22...+140 °F) T 60 Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V main/aux. circuit AC 3,000 V pole/pole AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity Icn 0.1...5 A 400 A 6...32 A 800 A curves F1, F2, M1, T1: 0.1...16 A 2,500 A (at DC 32 V) Interrupting capacity (UL 1077) Degree of protection operating area IP30 (IEC 60529/DIN 40050) terminal area IP20 Vibration curves F1, F2: 3 g (57-500 Hz), ± 0.23 mm (10-57 Hz) curves M1, T1: 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5 10 g (11 ms), direction 6 curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5 20 g (11 ms), direction 6 to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 60 g per pole IN 0.1...16 A 20...25 A AC 277 V 1-pole 5,000 A 2,000 A AC 277/480 V 2-/3-pole 5,000 A 2,000 A DC 65 V 2,000 A 2,000 A Preferred types Standard current ratings (A) 1-pole 0.5 1 2 3 4 5 6 8 10 16 20 2210-T210-K0M1-H121- x x x x x x x x x x x 2-pole 0.5 1 2 3 4 5 6 8 10 16 20 2210-T220-K0M1-H221- x x x x x x Preferred types NEW Thermal-Magnetic Circuit Breaker 2210-T2.. 3 - 18 www.e-t-a.de Issue D 3 Installation drawing Dimensions M1 12A Si-terminal M3 max. 1.5 mm2 (AWG 16) (rigid conductor) tightening torque 0.5 Nm .295 12-14 .472-.551 .354-.472 9-12 unit I unit II unit III 44 30.5 18 12.5 12.5 40 5.5 37.5 OFF ON 78.5 12.5 20 Si 1 Si 2 12 15 88.5 42.5 5.5 7.5 11.5 25 slot fitting labels from Phoenix Weidmüller Wieland G-profile EN 50035-G32 symmetric rail EN 50022-35x7.5 EN 50022-35x15/1.5 main contact terminal max. 6 mm2 (AWG 10) (rigid conductor) tightening torque 0.5 Nm M1 12A 45 .787 1.77 .217 1.67 1.57 .472 .591 toggles linked for multipole devices 11.5 .453 1.73 3.09 3.48 .709 .984 1.20 1.48 .453 .492 .492 .492 M1 12A .217 Si 1 Si 2 operating area (reinforced insulation) mounting area Standard current ratings and typical internal resistance values This is a metric design and millimeter dimensions take precedence ( mm ) inch Approvals Authority Voltage ratings Current ratings GL, VDE (EN 60934) 3 AC 433 V; AC 250 V; DC 65 V 0.1...32 A UL, CSA AC 277 V; AC 277/480 V; DC 65 V 0.1...32 A Current rating (A) Internal resistance (Ω) F1 F2 M1 T1 fast acting for DC only fast acting delay for AC + DC standard for AC+DC delayed low resistance for AC only 0.1 162 162 92 81 0.2 39.3 39.3 26.1 24.2 0.3 17.5 17.5 11.6 10.4 0.4 9.2 9.2 6.6 6.0 0.5 6.8 6.8 4.1 3.9 0.6 4.2 4.2 3 2.7 0.8 2.8 2.8 1.65 1.53 1 1.6 1.6 1.10 0.98 1.5 0.78 0,78 0.47 0.42 2 0.42 0,42 0.28 0.24 2.5 0.26 0.26 0.183 0.17 3 0.18 0.18 0.124 0.12 4 0.12 0.12 0.077 0.073 5 0.092 0.092 0.063 0.055 6 0.054 0.054 0.045 0.039 8 0.025 0.025 ≤ 0.02 ≤ 0.02 10 0.022 0.02 ≤ 0.02 ≤ 0.02 12 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 16 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 20 - - ≤ 0.02 ≤ 0.02 25 - - ≤ 0.02 ≤ 0.02 32 - - ≤ 0.02 ≤ 0.02 Thermal-Magnetic Circuit Breaker 2210-T2.. Issue D www.e-t-a.de 3 - 19 3 Trip time in seconds Trip time in seconds Trip time in seconds -F1 0.1…16 A DC only 0.001 1 2 4 6 8 10 20 40 10000 1000 100 10 1 0.1 0.01 6080100 -F2 8…16 A AC/ DC 1) 10000 0.001 0.001 1 2 4 6 8 10 20 40 1000 100 10 1 0.1 0.01 6080100 1 2 4 6 8 10 20 40 10000 1000 100 10 1 0.1 0.01 6080100 -F2 0.1…7.5 A AC/ DC 1) -30 °C -22 °F +23 °C +73.4 °F +60 °C +140 °F … times rated current … times rated current … times rated current 1) Magnetic tripping currents are increased by 30 % on DC supplies. Internal connection diagrams Typical time/current characteristics OFF position ON position N/O contact N/C contact 0 I 1 13 2 0 I 1 11 2 I > 0 I 1 13 2 0 I 1 11 2 line line line line (Si) (Si) (Si) (Si) (Si) (Si) 12 12 (Si) (Si) 14 14 I > I > I > ...-H131-... ...-H121-... 5 6 1 2 4 3 Shock directions Thermal-Magnetic Circuit Breaker 2210-T2.. 3 - 20 www.e-t-a.de Issue D 3 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Multi pole devices: all poles symmetrically loaded. With single pole overload, thermal tripping will be at max. 1.7 x IN with curves F1, F2 and M1. 1) Magnetic tripping currents are increased by 30 % on DC supplies (curves M1, T1). Ambient °F temp. °C -22 -30 -4 -20 +14 -10 +32 0 +73.4 +23 +86 +30 +104 +40 +122 +50 +140 +60 Derating factor 0.76 0.79 0.83 0.88 1 1.04 1.11 1.19 1.29 -T1 8…25 A AC only 100 10 1 0.1 0.01 0.001 Trip time in seconds 1 2 4 6810 20 40 10000 1000 6080100 … times rated current 100 10 1 0.1 0.01 0.001 Trip time in seconds 1 2 4 6810 20 40 10000 1000 6080100 … times rated current -M1 0.1…6 A AC/DC 1) -M1 8…25 A AC/DC -T1 0.1…6 A AC only 1) 100 10 1 0.1 0.01 0.001 Trip time in seconds 1 2 4 6810 20 40 10000 1000 6080100 … times rated current 100 10 1 0.1 0.01 0.001 Trip time in seconds 1 2 4 6810 20 40 10000 1000 6080100 … times rated current Typical time/current characteristics Thermal-Magnetic Circuit Breaker 2210-T2.. Issue D www.e-t-a.de 3 - 21 3 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. Accessories Art.-Nr. Y 308 498 01 IEC 664 500 V/100 A (40 °C) Art.-Nr. Y 308 498 01 IEC 664 500 V/100 A (40 °C) marking 4 x on busbar 79 x 12.5 = 987.5 12.5 3 4.6 14.7 1.5 30.7±0.4 16 Art.-Nr. Y 308 499 01 IEC 664 500 V/100 A (40 °C) Art.-Nr. Y 308 499 01 IEC 664 500 V/100 A (40 °C) marking 4 x on busbar 79 x 12.5 = 987.5 3±0.2 16 L2 L1 L2 L1 L1 L1 L2 L2 L1 L1 L2 L2 L1 L1 L2 L2 L1 L1 L2 L2 L1 L1 L2 L2 L1 L1 L2 L2 L1 L1 L2 L1 L2 L2 L1 995+2 995+2 15.8 33,3 17.3 ±0.4 ~2.76 Connector bus links -K10 X210 589 01/ 2.5 mm2, (AWG 14) (black) up to 20 A max. load X210 589 02/ 1.5 mm2, (AWG 16) (brown) up to 13 A max. load 50 pin lugs to DIN 46230 tinned copper ø2.5 .099 ~70 79 x 12.5 = 987.5 12.5 3±0.2 1.5 20-1 16-1 14.7 4.6 Busbar 1-pole, 90° X 222 540 01 The one metre long busbars can be cut to suitable lengths. Plug-on caps can be fitted on the ends to provide brush contact protection. Imax - busbar 100 A (40 °C) .118±.008 .492 79 x .492 = 38.878 .579 .181 .059 .630-.039 .787-.039 .118 .492 79 x .492 = 38.878 79 x .492 = 38.878 39.173+.079 .630 .181 .579 1.209±.016 .059 39.173+.079 .630 12.5 .492 .118±.008 1.5 .059 .622 .681 1.311±.016 Elektrotechnische Apparate GmbH D-90418 Altdorf bei Nürnberg Elektrotechnische Apparate GmbH D-90418 Altdorf bei Nürnberg Busbar 1-pole Y 308 498 01 Imax - busbar 100 A (40 °C) Plug-on cap, 1-pole Y 307 851 01 Busbar 2-pole Y 308 499 01 Imax - busbar 100 A (40 °C) Elektrotechnische Apparate GmbH D-90418 Altdorf bei Nürnberg Elektrotechnische Apparate GmbH D-90418 Altdorf bei Nürnberg Plug-on cap, busbar 2/3-pole Y 308 506 01 Plug-on cap, 1-pole Y 307 851 01 This is a metric design and millimeter dimensions take precedence ( mm ) inch Supply terminal Y 308 503 01 Imax 63 A with 1-pole busbar, 50 A with multipole busbar Max. tightening torque of terminal screw 2 Nm Max. cable cross section: 25 mm2 / single strand 16 mm2 / multistrand with wire end ferrule Art.-Nr. Y 308 500 01 IEC 664 500 V/100 A (40 °C) Art.-Nr. Y 308 500 01 IEC 664 500 V/100 A (40 C) ° marking 4 x on busbar 80 x 12.5 = 1000 12.5 3±0.2 L3 L1 L2 L2 L2 L3 L3 L1 L2 L2 L1 L3 L3 L1 L2 L2 L2 L2 L1 L3 L3 L1 L2 L2 L1 L3 L3 L1 L2 L2 L1 L3 L3 L2 L2 L2 1010+2 15.8 17.3 1.5 18.4 3 16.2 33.7 13 16 39.764+.079 .630 .492 118±.0082 80 x .492 = 39.370 .622 .681 33,3±0.4 1.311±.016 1.5 .059 .118 .059 .512 1.327 .638 .724 Elektrotechnische Apparate GmbH D-90418 Altdorf bei Nürnberg Elektrotechnische Apparate GmbH D-90418 Altdorf bei Nürnberg Busbar 3-pole Y 308 500 01 Imax - busbar 100 A (40 °C) Plug-on cap, busbar 2/3-pole Y 308 506 01 Caution: When using multipole busbars please leave at least one pole’s width between two adjacent line entry terminals. ETA Module 17plus 3AC433V / E-T-A Abschlussmodul - Partsmax Türkiye
 
------------------
One, two and three pole thermal-magnetic circuit breakers with trip-free
mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934).
Featuring a combi-foot design for both symmetric and asymmetric rail
mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status
signalling. Two and three pole models are internally linked to ensure that
both/all poles trip in the event of